| Temperature Range | • -40°C to +140°C (continuous) • Peak: +160°C (≤30 min) | IEC 60754 |
| Flame Rating | UL 94 V-2 (self-extinguishing) • Optional V-0 additive | UL 94 |
| Chemical Resistance | Resistant to: |
|
| • Hydraulic oils (ISO VG 32/46) |
|
|
| • Fuels (diesel, biodiesel) |
|
|
| • Coolants (glycol-based) |
|
|
| • Weak acids/alkalis (pH 4–10) | ISO 175 |
|
| Mechanical Strength | • Tensile strength: ≥78 MPa |
|
| • Crush resistance: ≥1,250 N/100mm |
|
|
| • Impact strength: 50 kJ/m² | ISO 527, ISO 7616, ISO 179 |
|
| Flexibility | Minimum bend radius = 4× OD (no collapse) | IEC 61386-21 |
| Hydrolysis Resistance | Retains >85% properties after 1,000 hrs @ 85°C/85% RH | ISO 4611 |
| UV/Ozone Stability | ΔE < 2.0 after 1,500 hrs Xenon-arc exposure | ISO 4892-2 |
| IP Protection | IP67/IP68 (submersible to 1.5m depth) | IEC 60529 |